Series Overview

Series Overview

A modular PLC inventory platform with a large installed base, focusing on serving MRO spare parts, fault replacement and migration needs to S7-1500.

Part-number Structure & Selection Notes

S7-300 purchases must be based on the complete MLFB. The same CPU name has multiple 6ES7 ordering codes under different hardware versions, interface combinations and security versions. You cannot place an order by just writing "CPU315".

Representative Models

These references support part-number identification and sourcing. Lifecycle status, regional versions, suffixes and specifications must be confirmed against the complete ordering code and current manufacturer documentation.

Complete MLFBCPUinterfaces / versionSourcing Scope
6ES7313-6CG04-0AB0CPU 313C-2 DPDPInstalled base
6ES7314-6CH04-0AB0CPU 314C-2 DPDPInstalled base
6ES7314-6EH04-0AB0CPU 314C-2 PN/DPPN/DPInstalled base
6ES7315-2AH14-0AB0CPU 315-2 DPDPInstalled base
6ES7315-2EH14-0AB0CPU 315-2 PN/DPPN/DPInstalled base
6ES7315-6FF04-0AB0CPU 315F-2 DPFail-safe / DPInstalled base
6ES7315-2FJ14-0AB0CPU 315F-2 PN/DPFail-safe / PN/DPInstalled base
6ES7317-2AK14-0AB0CPU 317-2 DPDPInstalled base
6ES7317-2EK14-0AB0CPU 317-2 PN/DPPN/DPInstalled base
6ES7317-2FK14-0AB0CPU 317F-2 PN/DPFail-safe / PN/DPInstalled base
6ES7318-3EL01-0AB0CPU 319-3 PN/DPPN/DPInstalled base
6ES7318-3FL01-0AB0CPU 319F-3 PN/DPFail-safe / PN/DPInstalled base

Legacy and region-specific products must be checked against the complete reference, nameplate and application conditions.

FAQ

Frequently Asked Questions

Is the S7-300 still available?

Different MLFBs have different life cycles and channel inventories and should be checked against the complete 6ES7 ordering code. There is continued MRO demand for high-installation models.

What is the successor platform to the S7-300?

New projects should usually evaluate SIMATIC S7-1500; the migration involves program, I/O, communication, rack and wiring, not a direct CPU swap.

CPU315-2 PN/DP Can I just write the name to inquire?

Not recommended. If there are different hardware/ordering versions of the same name, a complete MLFB or a clear photo of the nameplate must be provided.

Do old project procedures need to be provided together?

For migration assessment, it is best to provide STEP 7/TIA project information, module list and network topology; for pure original model spare parts procurement, MLFB is sufficient first.