Series
ACS880-01
ACS880-01 is ABB's high-performance single drive series, suitable for applications requiring high dynamic performance, strong overload capability, complex process control or a higher power range. Compared with general-purpose drives, this series requires a clear distinction between nominal-duty and heavy-duty parameters, which cannot be summarized by just one kW value.
The complete part number usually consists of ACS880-01, the rated current code and the voltage class suffix, for example -5 for 380–500V class. When selecting, check the rated current, PN, PHd, frame, braking/feedback requirements, control interface and optional code respectively. PN and PHd should not be mixed, especially when replacing old ACS800 or other high-performance drives, they must be reconfirmed according to the actual load.
| Model | Rated current | PN | PHd | frame | voltage |
|---|---|---|---|---|---|
| ACS880-01-02A1-5 | 2.1A | 0.75kW | 0.55kW | R1 | 380–500V |
| ACS880-01-11A0-5 | 11A | 5.5kW | 4kW | R1 | 380–500V |
| ACS880-01-021A-5 | 21A | 11kW | 7.5kW | R2 | 380–500V |
| ACS880-01-040A-5 | 40A | 22kW | 19kW | R4 | 380–500V |
| ACS880-01-077A-5 | 77A | 45kW | 37kW | R5 | 380–500V |
| ACS880-01-124A-5 | 124A | 75kW | 55kW | R6 | 380–500V |
| ACS880-01-180A-5 | 180A | 110kW | 90kW | R7 | 380–500V |
| ACS880-01-260A-5 | 260A | 160kW | 132kW | R8 | 380–500V |
The table shows verified representative models and key specifications. If your required model is not listed, send the complete ordering code for verification.
FAQ
Frequently Asked Questions
What are the main differences between ACS880-01-02A1-5 and ACS880-01-11A0-5?
rated current: ACS880-01-02A1-5 is 2.1A, ACS880-01-11A0-5 is 11A; PN: ACS880-01-02A1-5 is 0.75kW, ACS880-01-11A0-5 is 5.5kW; PHd: ACS880-01-02A1-5 is 0.55kW, ACS880-01-11A0-5 is 4kW. Verify the complete ordering code and project conditions before selection or replacement; the series name alone is not sufficient.
Which specifications matter most when selecting ACS880-01?
Key specifications to verify are rated current, PN, PHd, frame, voltage. Match them against the equipment nameplate, drawing or original model, and retain every suffix, option and regional code in the complete ordering reference.
Why is the complete part number required when requesting a quote for ACS880-01?
Models within ACS880-01 may differ in electrical ratings, construction, interfaces or accessories. For example, ACS880-01-02A1-5, ACS880-01-11A0-5, ACS880-01-021A-5 are distinct configurations and cannot be interchanged on the series name alone. Using the complete part number substantially reduces mismatch risk.
How should ACS880-01 be confirmed when used as spare parts for installed equipment?
For installed-base MRO involving ACS880-01, provide the original part number, nameplate photo, equipment application and quantity. We first verify the existing model and critical specifications, then check whether the original remains available. If migration is required, mounting, electrical, communication and accessory differences are compared separately.
Request a Quote for ACS880-01
Please provide the complete part number, quantity and destination country. For installed-base replacements, include the original model and nameplate details.